The house

What to fix on the house itself, from the vents to the roof, and who asks for each fix.

You'll be able to

  • Spot where embers get into a house, and which surfaces burn
  • Tell what the code requires when you build or replace, from what IBHS and insurers ask
  • Know the cheap fixes from the upgrades that wait for a replacement
  • Use the right words: noncombustible, ignition-resistant, Class A, ember-resistant, tempered

Last checked . We update the course when rules change.

Each fix in this lesson is labeled by who asks for it:

  • Law nowthe defensible space law: roof and gutters clear [1]
  • WUI Codethe WUI Code: new work and roof replacements [2]
  • IBHSWildfire Prepared Home, voluntary [3]
  • Discountthe Safer from Wildfires list [4]
  • AdviceCAL FIRE and UC Cooperative Extension [5][6]

15 short cards, then a 10-question quiz. Tap any underlined word to see what it means. Or scroll down to read it as one page.

Openings and surfaces

A house with its weak points numberedA house in side view, with a deck on the left and an attached garage on the right. Orange markers show openings where embers get in: 3 a gable vent, 4 the eaves, 5 the garage door gaps. Blue markers show surfaces that flames and heat attack: 6 a window, 7 the roof, 8 the gutter, 9 the bottom of the wall, 10 the deck. The numbers match the cards. 345678910

Embers get in through openings: vents, gaps, the eaves.

Flames and heat attack surfaces: the roof, walls, windows, deck.

The numbers match the cards.

No state law makes you upgrade an existing house all at once. But when you replace a part, the new part often has to meet the code (card 14). And insurers and buyers ask for upgrades.

New terms: WUI CodeTap an underlined word to see what it means.

What matters most

Researchers looked at more than 40,000 California buildings exposed to wildfires from 2013 to 2018.

The house features most often linked to survival: enclosed eaves, screened vents and multipane windows [7].

In the 2018 Camp Fire, one of the strongest signs was how close the nearest burning house was [8].

No single order fits every home. The house, the first 5 feet and your neighbors work together.

This lesson starts with the openings.

Vents

Why:ProtectInsurance

Vents let air into the attic and crawlspace. Embers ride in with it.

Close-up drawing of a louvered attic vent high in a gable wall. Embers blow at it and stop at the fine metal mesh behind the slats.

Attic (gable) vent

Close-up drawing of a short, wide crawl-space vent at the bottom of a wall, covered with fine metal mesh. Embers blow across the gravel and stay outside.

Crawl-space vent

Both have 1/8-inch metal mesh, as IBHS asks.
  • WUI CodeEmber-resistant vents listed by the State Fire Marshal, or, for some roof vents, metal mesh with holes 1/16 to 1/8 inch [2].
  • IBHSEssential: ember-resistant vents, or 1/8-inch corrosion-resistant metal mesh, on attic, ridge, soffit, gable and foundation vents [3].
  • IBHSDryer vent: a working flap, not mesh [3].
  • AdviceCommon 1/4-inch screen lets embers through. Finer mesh clogs faster, so clean it [6].

Finer than 1/8 inch isn't required at either level. It blocks more but clogs faster.

Three mesh sizes side by sideThree squares of screen, drawn to the same scale. 1/4-inch mesh has holes big enough for an ember to pass through. 1/8-inch mesh is the most IBHS and the code allow. 1/16-inch mesh is finer and clogs faster. 1/4 inchLets embers in 1/8 inchCode and IBHS max 1/16 inchClogs faster

Eaves

Why:ProtectInsurance

Open eaves and enclosed eaves, cut throughTwo cutaway views where the roof meets the wall. Left, open eaves: the rafter tails show from below, and heat and embers collect in the pockets between rafters, against the wall. Right, enclosed or boxed eaves: a soffit panel closes off the underside, so the rafters are hidden. Open eavesEnclosed (boxed) eaves Rafter tails show Heat and emberscollect here Wall Rafters, hidden Soffit Wall

With open eaves, heat and embers collect in the pockets between rafters.

  • DiscountEnclosed eaves are on the required discount list [4].
  • IBHSEnhanced requires eaves enclosed with noncombustible material. Essential doesn't [3].
  • WUI CodeSeveral materials and designs are allowed. Enclosing isn't the only way [2].
  • AdviceSeal gaps over 1/8 inch where the rafters meet the wall [9].

New terms: Soffit

Gaps and the garage door

Why:ProtectInsurance

A gap is an open door for embers.

  • WUI CodeNew garage doors: no gap over 1/8 inch at the bottom, sides or top. Weatherstripping, overlaps or metal flashing close it [2].
  • IBHSNo gap number in either level [3].
  • AdviceReplace worn garage door seals. Seal gaps over 1/8 inch around siding and eaves [9].
A garage door with its three gaps markedA closed garage door in its frame. Gaps are marked at the top, along both sides and at the bottom. For new doors, the WUI Code allows no gap over 1/8 inch at any of them. Top Sides Bottom No gapover 1/8 inchNew doors

Garages hold cars, fuel and storage. An ember that gets in finds plenty to burn.

Windows and skylights

Why:ProtectInsurance

Heat can break glass before flames arrive. Then embers get in.

  • WUI CodeNew windows: at least two panes, one of them tempered, or other approved glass [2].
  • IBHSEnhanced: two tempered panes. Essential: no window rule [3].
  • DiscountMultipane windows, or full shutters [4].
  • WUI CodeOperable skylights: 1/8-inch metal mesh [2].

Tempered glass handles about 3 to 4 times more heat than ordinary glass [6].

Vinyl frames can sag in heat [6]. Shutters only help if someone closes them.

New terms: Tempered glass

Roof

Why:ProtectLawInsuranceSale

The roof is a big landing spot for embers, especially in valleys where needles collect [6].

  • Law nowKeep it clear of leaves and needles, valleys included [1].
  • WUI CodeA Class A roof for new and replaced roofs. Roofs with an airspace underneath, like tile, need bird stops at the eaves [2].
  • IBHSClass A, and no wood shakes or shingles at all, even rated ones [3].

Class A is the top rating in standard fire tests. Asphalt shingles, metal, tile and slate are commonly Class A. Some only rate Class A with the right layer underneath [6].

New terms: Bird stop

Gutters

Why:ProtectLawInsurance

Leaves in a gutter sit right against the roof edge.

  • Law nowKeep them clear [1].
  • WUI CodeNoncombustible gutters and downspouts, with a way to keep debris out [2].
  • IBHSEssential: noncombustible, kept clear. Enhanced adds a noncombustible gutter cover [3].

Gutter covers aren't on the required discount list [4].

Siding and the bottom 6 inches

Why:ProtectInsurance

Embers pile up where the wall meets the ground or a deck.

  • WUI CodeNew walls: noncombustible, ignition-resistant or approved treated siding, and 6 inches of metal flashing or noncombustible material at the ground, deck and roof lines [2].
  • IBHSBoth levels: the bottom 6 inches noncombustible, measured from the ground or from a deck or patio. Concrete, fiber cement, brick, stone, stucco or metal flashing count. Enhanced: noncombustible siding everywhere [3].
  • DiscountA noncombustible bottom 6 inches [4].

New terms: Ignition-resistant Flashing

Decks

Why:ProtectLawInsurance

  • Law nowNothing that can burn stored under the deck [1].
  • IBHSEssential: decks 4 feet high or less enclosed with 1/8-inch metal mesh; post bases protected; the deck's own 5-foot zone. Enhanced: a solid, noncombustible deck surface [3].
  • WUI CodeNew decks: tested decking, and 6‑inch flashing where the deck meets the wall [2].
  • AdviceEmbers lodge in the gaps between boards [10]. UC says enclosing a clean deck may add little, and can trap moisture [11].
A low deck from the sideA deck attached to a house wall, cut through. Embers lodge in the gaps between deck boards. Metal mesh skirting closes the space under the deck. A 6-inch strip of metal flashing covers the wall where the deck meets it. Embers lodge in board gaps Meshskirting 6-inch flashing

IBHS and UC disagree on enclosing. Clear underneath either way.

Doors, chimneys and things attached

Why:ProtectInsuranceNeighbors

  • WUI CodeNew exterior doors: noncombustible, solid-core wood, or fire-rated [2].
  • AdviceA spark arrester on the chimney [9].
  • IBHSPergolas and patio covers: their own 5-foot zone, and either open slats or a Class A roof [3].

Fences touching the house: Lesson 5.

New terms: Spark arrester

What Enhanced adds

Why:ProtectInsurance

Wildfire Prepared Home has two levels. Enhanced asks for everything in Essential, plus [3]:

  • Eaves enclosed with noncombustible material
  • Two tempered panes in windows and glass doors, or fire-rated glass
  • Noncombustible siding everywhere
  • A noncombustible gutter cover
  • A solid, noncombustible deck surface, with no gaps
  • Dryer vent flaps made of metal or another noncombustible material
  • Exterior doors: noncombustible, solid-core wood, or fire-rated
  • Pergolas, patio covers and the undersides of balconies: noncombustible
  • Sheds, garages and playsets at least 30 feet from the house
  • No back-to-back wood fences less than 5 feet apart

Some insurers reward Enhanced more (Lesson 4) [15].

Cheap fixes first

Why:All five

CAL FIRE's low-cost list, updated January 1, 2026 [9]:

  • Bird stops, gutter covers and a chimney spark arrester
  • Ember-resistant vents
  • Gaps over 1/8 inch sealed
  • Garage door weatherstripping
  • Screens on operable skylights
  • 6-inch flashing where a deck meets the wall
  • Clean roofs, gutters and decks, and nothing stored underneath

Selling a home built before 2010 in a High or Very High fire hazard zone? You disclose this list and which items you did [12].

Bigger upgrades (roof, windows, siding, decking) are best done when the part is due anyway. Lesson 7 puts it in order.

When you upgrade or replace

Why:LawInsuranceSale

  • Roof: replacing half or more within 12 months means the new roof must meet the code, so Class A [13].
  • Windows, doors, siding, decks: the new parts must meet the WUI Code where it applies (card 6 for windows, cards 9 to 11 for the rest) [2]. On an older home, ask your building department first; the rules for older homes have been changing.
  • Permits: many of these jobs need one [14].
  • Insurers: each upgrade can count toward discounts or Wildfire Prepared Home (cards 4 to 12, Lesson 4).

When you replace anyway, the better material often costs little more.

The Home Ready Wildfire Complete Course, Modules 2 and 3, goes deeper.

This weekend

Why:ProtectLawInsurance

  1. 1

    Clear the roof, valleys too, and the gutters. Move anything stored under the deck [1].

  2. 2

    Check your vents. Common 1/4-inch screen lets embers in; 1/8-inch metal mesh or ember-resistant vents keep them out. A dryer vent gets a working flap, not mesh [3][6].

  3. 3

    Replace worn garage door seals, and seal gaps over 1/8 inch around siding and eaves [9].

Glossary

Every term used in this lesson.

Defensible space law
Public Resources Code 4291 on state-protected land, and Government Code 51182 in Very High fire hazard zones on locally protected land. It requires up to 100 feet of cleared and thinned space around a building, and a roof and gutters kept clear. Lesson 3 covers who has to follow it.
WUI Code
The California Wildland-Urban Interface Code (Title 24, Part 7), the state's building rules for fire hazard zones, in effect January 1, 2026. It covers new buildings and roof replacements. It doesn't make you upgrade what's already there. Lesson 3 covers it.
Wildfire Prepared Home
A voluntary designation from IBHS for homes that meet its wildfire standard. Two levels: Essential protects against embers; Enhanced adds protection from flames and radiant heat. Lesson 4 covers it.
Safer from Wildfires
The Department of Insurance rule that makes every insurer give a discount for a set list of wildfire safety steps. Lesson 4 covers it.
CAL FIRE
The California Department of Forestry and Fire Protection, the state's fire agency. It publishes home hardening advice and the low-cost retrofit list.
UC Cooperative Extension
The University of California's local research and advice offices, with advisors in most counties. Part of UC Agriculture and Natural Resources (UC ANR).
Enclosed eaves
Eaves are the edge of the roof that hangs past the walls. Enclosed eaves have a solid covering underneath, so you can't see the rafters from below: either a flat, boxed-in soffit, or panels that follow the slope of the rafters. With open eaves the rafters show. Lesson 4 covers them.
Multipane windows
Windows with two or more layers of glass. They hold up to a fire's heat longer than single-pane windows. Lesson 4 covers them.
Ember-resistant vents
Vents built and tested to keep out embers and flames. The State Fire Marshal lists approved models. Lesson 4 calls them fire-resistant vents.
Soffit
The panel that closes off the underside of the eaves, so the rafters are hidden. Eaves with a soffit are enclosed, or boxed, eaves.
Tempered glass
Glass that's heat-treated to be about four times stronger than ordinary (annealed) glass. It holds up much better to a fire's heat. A small mark etched in one corner shows a pane is tempered.
Class A roof
A roof covering with the top rating in standard fire tests. Some coverings rate Class A on their own; others only with the right layer underneath. Lesson 4 covers it.
Bird stop
A filler piece that closes the open ends under the first row of a tile or similar roof, at the eaves. It keeps out birds, and embers and debris too.
Noncombustible
Won't burn. Gravel, stone, concrete, brick and metal are noncombustible. Wood and vinyl are not. Lesson 4 covers it.
Ignition-resistant
A material that resists catching fire, tested to a state standard, like exterior fire-retardant-treated wood. It isn't noncombustible: it can still burn.
Flashing
A strip of metal or other noncombustible material that covers a joint, like where a wall meets the ground, a deck or a roof.
Spark arrester
A metal mesh screen over the top of a chimney or stovepipe that keeps sparks from flying out. CAL FIRE's list calls for openings of 3/8 to 1/2 inch.
Fire hazard zone
Short for Fire Hazard Severity Zone: land the State Fire Marshal maps as Moderate, High or Very High for wildfire hazard. Lesson 3 covers it.

Want to go deeper?

Optional. These go further than the lesson.

On our sites

From the experts

Sources

  1. California Public Resources Code section 4291 and 14 CCR 1299.03 (roof and gutters clear, no branches within 10 feet of a chimney, nothing under decks).
  2. 2025 California Wildland-Urban Interface Code, Chapter 5 (sections 504.2 roof, 504.3 eaves, 504.4 gutters, 504.5 walls, 504.7 decks, 504.8 glazing, 504.9 doors and garage doors, 504.10 vents), in effect January 1, 2026. A free readable copy.
  3. IBHS, Wildfire Prepared Home Technical Standard, version December 2025 (PDF, effective June 1, 2026).
  4. California Code of Regulations, title 10, section 2644.9 (Safer from Wildfires) (also in Lesson 4).
  5. CAL FIRE, "Home Hardening".
  6. UC ANR Fire Network, "Vents", "Roof" and "Windows"; and Restaino and others, "Wildfire Home Retrofit Guide," University of Nevada, Reno Extension and UC Cooperative Extension, 2020.
  7. Syphard and Keeley, "Factors Associated with Structure Loss in the 2013–2018 California Wildfires," Fire, 2019.
  8. Knapp, Valachovic, Quarles and Johnson, "Housing arrangement and vegetation factors associated with single-family home survival in the 2018 Camp Fire, California," Fire Ecology, 2021.
  9. CAL FIRE, "Low-Cost Retrofit List," updated January 1, 2026 (PDF).
  10. IBHS, "Vulnerability of Decks to Embers and Flames".
  11. UC ANR Fire Network, "Deck".
  12. California Civil Code section 1102.6f (selling a home built before 2010 in a High or Very High fire hazard zone).
  13. 2025 California Wildland-Urban Interface Code, section 507.1 (replacement or repair of roof coverings).
  14. City of Santa Rosa, "Building Permits" (an example; your city or county has its own page).
  15. Resources for the Future, "From Risk to Reward," Working Paper 25-30, December 2025 (PDF; the largest discounts went to Wildfire Prepared Home Plus, now called Enhanced; also in Lesson 4).

Written by Devan Hemmings. Sources last checked November 7, 2026. General information for learning, not an inspection or legal advice.